Page 41 Volume 17 - N.4 - 2009
P. 41
Dor (2009) 17
33. Pedersen JG, Lund B, Reimann I. Depressive effects of acrylic ce- kyphoplasty: a systematic review of the literature. Eur Spine J.
ment components on bone metabolism. Isotope release and phos- 2009;18:1257-65.
phatase production studied in vitro. Acta Orthop Scand. 1983;54: 41. Buchbinder R, Osborne RH, Ebeling PR, et al. A randomized trial of
796-801. vertebroplasty for painful osteoporotic vertebral fractures. N Engl J
34. Horowitz SM, Doty SB, Lane JM, Burstein AH. Studies of the Med. 2009;361:557-68.
mechanism by which the mechanical failure of polymethyl- 42. Kallmes DF, Comstock BA, Heagerty PJ, et al. A randomized trial of
methacrylate leads to bone resorption. J Bone Joint Surg Am. vertebroplasty for osteoporotic spinal fractures. N Engl J Med.
1993;75:802-13. 2009;361:569-79.
35. Sturup J, Nimb L, Kramhoft M, Jensen JS. Effects of polymerization 43. Voormolen MH, Mali WP, Lohle PN, et al. Percutaneous vertebro-
heat and monomers from acrylic cement on canine bone. Acta Or- plasty compared with optimal pain medication treatment: short-term
thop Scand. 1994;65:20-3. outcomes of patients with subacute or chronic painful osteoporotic
36. Luk AS, Winet H, Bao JY. Effect of polymethylmethacrylate particles vertebral compression fractures. The VERTOS study. AJNR Am J
on mature bone in the optical bone chamber. J Biomed Mater Res. Neuroradiol. 2007;28:555-60.
2001;55:177-84. 44. Wardlaw D, Cummings SR, Van Meirhaeghe J, et al. Efficacy and
37. Libicher M, Hillmeier J, Liegibel U, et al. Osseous integration of safety of balloon kyphoplasty compared with nonsurgical care for
calcium phosphate in osteoporotic vertebral fractures after kyphop- vertebral compression fracture (FREE): a randomised controlled
lasty: initial results from a clinical and experimental pilot study. Os- trial. Lancet. 2009;373:1016-24.
teoporos Int. 2006;17:1208-15. 45. Korovessis P, Zacharatos S, Repantis T, Michael A, Karachalios D.
38. Boszczyk B. Prospective study of standalone balloon kyphoplasty Evolution of bone mineral density after percutaneous kyphoplasty in
with calcium phosphate cement augmentation in traumatic fractures fresh osteoporotic vertebral body fractures and adjacent vertebrae
(G. Maestretti et al.). Reviewer’s comment. Eur Spine J. 2007; along with sagittal spine alignment. J Spinal Disord Tech.
16:611. 2008;21(4):293-8.
39. Pitton MB, Herber S, Koch U, Oberholzer K, Drees P, Düber C. CT- 46. Maestretti G, Cremer C, Otten P, Jakob RP. Prospective study of
guided vertebroplasty: analysis of technical results, extraosseous standalone balloon kyphoplasty with calcium phosphate cement
cement leakages, and complications in 500 procedures. Eur Radiol. augmentation in traumatic fractures. Eur Spine J. 2007;16:601-10.
2008 Jun 4. Epub ahead of print. 47. AAOS Issues New Treatment Guidelines for Symptomatic Osteoporotic
40. Krueger A, Bliemel C, Zettl R, Ruchholtz S. Management of pulmo- Spinal Compression. MedscapeCME Clinical Briefs. CME Released:
nary cement embolism after percutaneous vertebroplasty and 10/04/2010.
DOR
40